I tried to update to v. 3.8.22.0 an LHG XL HP5 from remote, but now it is no more connected to the mesh. I tried a hardware reset (power cycle) without results.
I think the update process has not ended or something went wrong. In fact, the node has not resumed automatically and I had to click on the red link.
What can I do to recover it?
Thanks for help.
I think the update process has not ended or something went wrong. In fact, the node has not resumed automatically and I had to click on the red link.
What can I do to recover it?
Thanks for help.
Thanks.
Is your computer getting an IP address from the LHG via DHCP?
If you put the LHG into TFTP mode, can you PING 192.168.1.1 ?
73, Chuck
thanks for answering!
I suppose my computer is not getting an IP address. The LED on the port is blinking for a few seconds and then off.
Can't do the 30-second reset because it's up the roof. I will try it as soon as I'll pull it down and let you know later.
73, Leo
At one time you had a Ubiquiti M5.
Still have it?
Does its POE have a reset button?
If yes:
Try the 5 second failsafe procedure,
Try the 15 second failsafe procedure.
Try to put the LHG into TFTP mode and see if it responds to a ping to 192.168.1.1.
I think.
73, Chuck
Thanks for your suggestions.
73, Leo
73
Orv W6BI