You are here

HW Reset Button Functionality?

4 posts / 0 new
Last post
K5RA
HW Reset Button Functionality?
 

The AREDN documentation has the following:
 

Node Reset Button Actions

The reset button on an AREDN® node has two built-in functions based on the length of time the button is pressed.

With the node powered on and fully booted:

  • Hold for 5 seconds to reset the password and DHCP service
  • Hold for 15 seconds to return the node to “just-flashed” condition



I am assuming that "just-flashed" means the radio is back to Basic_Setup condition, with a default node name and default username and password.

I tried this with a configured nanoStation Loco M2 (XM) with 3.23.8.0 firmware. After a five-second Reset activation, the radio went back to Basic_Setup condition. 

I did the setup again (several times), and tried 2-3 sec activations of Reset.  This did change the node password back to default, but left other configurations unchanged.  

What is different now so that the Reset button response on my radio does not match the AREDN documentation?  This radio is probably 7 years old.

Thanks.

--Tim K5RA
 

KG7LMI
KG7LMI's picture
Re: HW Reset Button Functionality?
I noticed the same thing last week and logged the problem in github. See #869. It's already in work.

73, Rob
K5RA
HW Reset Timing

Rob -

Thanks for the update.  The info on EDR #869 is an interesting read.  I'd be tempted to try removing the /etc/ file from my nanoLoco, but would probably just brick a perfectly good old radio.

--Tim K5RA
 

KG7LMI
KG7LMI's picture
Re: HW Reset Timing
I ran the test requested in the EDR today and the node reset the password without restoring the node to firstboot state. So it looks like they're on the right track to fixing this.

73, Rob
 