We have the following 2 node devices:
- Bullet M2 HP
- Bullet M5
An ethernet cable has been used on the 24V POE adapters to cause dtd linking however that is not working.
- On the Bullet M2 HP we never saw any '(dtd)' link with the 5 GHz device.
- On the Bullet M5 we did see '(dtd)' with the 2.4 GHz device at one point but now we see '(tun)'.
Both devices are running firmware 3.18.9.0.
No tunnels are nor have been installed on either of these devices.
I have rebooted both devices several times and it makes no difference.
I reloaded 3.18.9.0 on the 5 GHz device and that made no difference.
I turned off dhcp server on the 5 GHz device and that made no difference.
Both devices seem to be otherwise be working okay.
Any ideas?`
Thanks, Mike ab4yy
Joe AE6XE
Done.
Thanks, Mike
The OLSR data shows the 5GHz is receiving 100% hello packets from the 2GHz on the dtdlink interface, but the reverse is not true. OLSR on the 2GHz is not receiving hello packets from the 5GHz. Symptoms can be caused by a cable issue. replace cat5, inspect all the female RJ45 connectors for foreign objects and corrosion, etc...
Just at boot time, there were a lot of network bouncing issues on the 2GHz.
Joe AE6XE
----------on 2GHz------------
Thanks Joe.
The nodes are not mine but I have made the request to the responsible person. It may be a while before he can get to it.
73 - Mike ab4yy