Recently upgraded a Nano Loco M2 to 3.18.9.0. It will not provide the info to Winlink Express to obtain WL2k post office info.
All the other nodes on the mesh (Bullets, Air Grids, Rockets) running 3.18.9.0 do provide the info.
If I swap out the LocoM2 for an AirGrid (which isn't practical for permanent install) then the issue goes away, so its got to be LocoM2 related.
Winlink would report: Error getting master node info. Unable to get info from master node ve7ahe-ecommtrailer.local.mesh
Your computer must be connected to an AREDN MESH node running firmware version 3.17.1.0RC1 or later.
Here is the JSON file output it makes.
{
"lon": "",
"sysinfo": {
"uptime": "0 days, 8:26:21",
"loads": [
0,
0.029999999999999999,
0
]
},
"interfaces": [
{
"name": "eth0.1",
"mac": "68:72:51:5D:4A:F5"
},
{
"mac": "68:72:51:5C:4A:F5",
"name": "wlan0",
"ip": "10.92.74.245"
},
{
"mac": "68:72:51:5D:4A:F5",
"name": "eth0",
"ip": "10.137.94.161"
},
{
"mac": "68:72:51:5D:4A:F5",
"name": "eth0.2",
"ip": "10.93.74.245"
}
],
"api_version": "1.5",
"services": [
{
"name": "WINLINK POSTOFFICE",
"protocol": "tcp",
"link": "http:\/\/VE7URC1-oldPO-POSTOFFICE:0\/"
},
{
"name": "POSTOFFICE",
"protocol": "tcp",
"link": "http:\/\/AARC-PO:0\/"
},
{
"name": "WINLINK POSTOFFICE",
"protocol": "tcp",
"link": "http:\/\/AARC-PO:0\/"
},
{
"name": "POSTOFFICE",
"protocol": "tcp",
"link": "http:\/\/POSTOFFICE:0\/"
},
{
"name": "Admin",
"protocol": "tcp",
"link": "http:\/\/VA7NIC-ER-X:80\/"
},
{
"name": "WINLINK POSTOFFICE",
"protocol": "tcp",
"link": "http:\/\/POSTOFFICE:0\/"
},
{
"name": "FILES",
"protocol": "tcp",
"link": "ftp:\/\/POSTOFFICE:21\/"
},
{
"name": "HELP",
"protocol": "tcp",
"link": "http:\/\/POSTOFFICE:80\/"
},
{
"name": "Admin",
"protocol": "tcp",
"link": "http:\/\/VE7URC-Switch:80\/"
},
{
"name": "WINLINK POSTOFFICE",
"protocol": "tcp",
"link": "http:\/\/Library1:0\/"
},
{
"name": "Admin",
"protocol": "tcp",
"link": "http:\/\/HP-G60-230CA:3389\/"
},
{
"name": "Admin",
"protocol": "tcp",
"link": "http:\/\/VA7PAM-ER-X:80\/"
}
],
"meshrf": {
"chanbw": "20",
"ssid": "BroadbandHamnet-20-v3",
"channel": "-2"
},
"tunnels": {
"active_tunnel_count": "0",
"tunnel_installed": false
},
"lat": "",
"grid_square": "",
"node": "VE7AHE-ECommTrailer",
"node_details": {
"firmware_version": "3.18.9.0",
"board_id": "0xe0a2",
"firmware_mfg": "AREDN",
"model": "NanoStation Loco M2 "
}
}
Yes, all 18 nodes on our mesh have been upgraded to 3.18.9.0 (which I might add is running really well except this hiccup)
I have discussed this with the Winlink developer and may review it again to see where we are on this.
Once I put the co-ordinates in, the Winlink Postoffice services detection started working.
I have 1 other node to test this theory against.