I have a remote M2 Rocket node that I was going to upgrade to the latest firmward but accidently got off with loading the wrong patch.
- Current FW ver is: 3.16.1.0
- Intent was to load v3.16.1.1 OTA Fixup Patch (patchFixAREDN31611SysUpgrad.tgz)
- Mistakenly loaded V3.15.1.0 Sysupgrade Patch (patch-sysupgrade3.tgz)
- The node rebooted okay but when I try tp go into Setup, I get this error:
Bad Gateway
The process did not produce any response
I am not able to go to the Setup screen and always get the one above.
Note that I am able to ssh into the node and should be able to add, remove or change files in the node.
Any help would be appreciated.
73 - Mike ab4yy
/etc/config.mesh/uhttpd
/usr/local/bin/spawn_sysupgrade
/usr/local/bin/upgrade_kill_prep
/www/cgi-bin/admin
/www/cgi-bin/perlfunc.pm
(If the files don't exist on your 3.16.1.0 node, you can ignore them on the broken node)
Thanks! I used 7-zip to extract a 3.16.1.0 firmware into a directory in Windows 7 then used WinSCP to copy the desired files from there to the node OTA. It was super easy.
73 - Mike ab4yy