You are here

Reset MIKROTIK hAP ac lite

5 posts / 0 new
Last post
KI0KY
Reset MIKROTIK hAP ac lite

I have done something to the MIKROTIK hAP ac lite so that using a either net cable to a lan port entering localnode.local.mesh:8080 returns "localnode.local.mesh's server address could not be found." I have tried three times to reset the unit using the power off, press reset with power on.
Suggestions please.
Steve KI0KY

w6bi
w6bi's picture
Testing.
You didn't say if it was configured or not.  If it's not, can you ping 192.168.1.1?   You might try that even if it was configured; if it responds, it's reverted to the unconfigured state.

Orv W6BI
KI0KY
Orv,
Orv,
192.168.1.1 did the trick.  What is the correct sequence of connecting the power and pressing the reset switch for what I need to know for AREDN.  It appears there are several combinations for rebooting.
THANKS,
Steve
w6bi
w6bi's picture
Info here!
I knew I'd seen it in the AREDN Online docs.  It's here: https://arednmesh.readthedocs.io/en/latest/arednGettingStarted/advanced_...

Orv
kk6ffz
a
Hold for 5 seconds to reset the password and DHCP service
Hold for 15 seconds to return the node to “just-flashed” condition

I did the 15 second hold and was able to log in again. Make sure you turn on get a dhcp address automatically instead of keep a static ip.... That was my problem last week :)

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer