Has anyone around experienced any issues with PowerBeam M5's (in our case the 400's) and 3.19.3.0 where after a period of time, they go offline for no apparently reason?
The one time we were able to get onto a unit after it went down via a dtdlink and using an IP address that was a bridge from the dtd device, any command ran via ssh resulted in an out of memory error.
If you don't catch it right away, you have to power cycle it to come back online.
We have had 4 of these units now go sideways since 3.19.3.0 came out. We've backed down to 3.18.9.0 to see if that cures the issue.
I hadn't seen any traffic regarding this but I figure we can't be the only ones with this issue...
Anyone?
Nick
VA7NIC
Out of the box these devices support 300Mbps throughput, so their Ethernet port runs 1000 Mbps. You need to manually configure your node to not negotiate and force a 100Mbps connection.
Andre, K6AH
There's some guessing currently, if/when the device has symptoms in future, be sure to try and access through all methods, LAN device, DtDLink, RF mesh and see if a support download can be obtained. We could be off on a tangent and not know it...
Joe AE6XE